If you have been reading about research chemical and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2026-01-06. Where a claim depends on a specific study, the study is described rather than over-claimed.
Regulatory treatment of SR9009 reflects its investigational status. The compound has no approved human therapeutic indication, and sports authorities prohibit its use. It appears on anti-doping lists as a non-approved substance or metabolic modulator, depending on the list version. Products sold online as research chemicals are not quality-controlled medicines, so their identity and purity can differ from the label. Such products may also contain unlisted compounds, which complicates both testing and safety assessment.
Scientific discussion of SR9009 often separates animal evidence from human anecdote. Rodent studies provide controlled data on endurance, metabolism, and gene expression, but they use specific strains, doses, and treatment durations. Human reports are mostly uncontrolled and cannot establish cause and effect. Open questions include oral bioavailability, tissue distribution, metabolic stability, and long-term effects. Review articles generally call for more rigorous pharmacokinetic and safety research before any clinical use could be considered.
Analytical methods for SR9009 typically rely on liquid chromatography coupled with tandem mass spectrometry. The technique can separate the parent compound from related substances and detect low concentrations in biological matrices. Urine and blood are common samples in anti-doping testing, while in vitro studies may use cell culture media. Rapid metabolism and low expected concentrations make method validation important for reliable identification. Exact metabolite patterns can vary by species and are not fully mapped.
Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.
SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.
For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.
| Property | Value | Notes |
|---|---|---|
| Regulatory status | Not approved for human use | Investigational status in most countries |
| Sports status | Prohibited by WADA | Classified as non-approved or metabolic modulator |
| Common analytical method | LC-MS/MS | Used for trace detection in biological samples |
| Typical test matrices | Urine and blood | Sample choice depends on testing program |
| Human trial data | None published | Effects and safety are not established |
At the molecular level, SR9009 binds the ligand-binding domain of REV-ERB and strengthens recruitment of corepressor proteins such as NCoR and HDAC3. This increases repression of target genes, including Bmal1 and other clock-controlled and metabolic genes. In rodent studies, such changes have been linked to altered lipid handling, glucose metabolism, and energy expenditure. The precise chain of events between receptor binding and whole-body effects remains an active area of research. Findings in animals do not automatically translate to humans.
Laboratory studies often administer SR9009 by injection because oral absorption appears poor in rodents. Reported pharmacokinetic properties include rapid metabolism and low systemic exposure after oral dosing. Human pharmacokinetic data are sparse, so absorption, distribution, metabolism, and excretion in people are not well defined. Some research explores related REV-ERB compounds with improved drug-like properties. Regulatory approval for any REV-ERB agonist as a human medicine has not been granted to date.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ, also called NR1D1 and NR1D2. These receptors help regulate circadian rhythms and metabolic gene programs. The compound was developed for laboratory research, not as an approved therapeutic. Its identity is distinct from steroid hormones and selective androgen receptor modulators. Scientific interest centers on how REV-ERB activation changes gene expression in cells and animal models.
Laboratory samples of SR9009 are typically handled as research chemicals rather than pharmaceuticals. Suppliers usually state that the material is for research use only and not for human or veterinary administration. Storage recommendations generally call for a freezer at approximately −20 °C, protection from light, and a desiccated environment. The solid is often described as a white to off-white powder. Solubility is commonly reported in organic solvents such as dimethyl sulfoxide and ethanol, with low solubility in water.
Analytical identification and purity assessment often use high-performance liquid chromatography with ultraviolet detection or mass spectrometry. Liquid chromatography–tandem mass spectrometry is used to detect and quantify SR9009 in biological matrices, including urine and blood, for anti-doping or pharmacokinetic studies. Nuclear magnetic resonance spectroscopy can confirm molecular structure. Stability depends on form and storage: the solid is generally more stable than solutions, and repeated freeze–thaw cycles may degrade samples. Purity is typically reported as a percentage from a certificate of analysis.
Regulatory treatment of SR9009 varies by country and context. It is not approved as a therapeutic drug by agencies such as the United States Food and Drug Administration or the European Medicines Agency. Sports authorities list it as a prohibited substance; the World Anti-Doping Agency classifies it among hormone and metabolic modulators. Legal status for personal possession or sale differs across jurisdictions, and some countries may restrict it under analog or research chemical laws. Buyers who seek verified material often rely on independent laboratory testing because online product labels may not match contents.
Detection of SR9009 in biological samples usually employs liquid chromatography coupled with tandem mass spectrometry. This method can identify the parent compound and sometimes metabolites in urine or blood. Because exposure can be low and clearance may be rapid, sample timing and limits of detection matter. Laboratories validate assays for sensitivity and specificity. Results are interpreted alongside chain-of-custody and quality-control records. Urine is the common matrix for anti-doping analysis, while blood may be used in research settings.
Handling recommendations for SR9009 in a laboratory setting include storing the solid at low temperature, protected from light and moisture. The compound is often dissolved in dimethyl sulfoxide or ethanol for experiments. Solutions should be prepared with appropriate personal protective equipment and disposed of according to local rules. Stability data for long-term storage are limited, so stock solutions are typically kept cold and used within defined periods. Records of preparation date and concentration support reproducibility.
SR9009 is not approved as a medicine by major regulatory agencies. It is commonly sold as a research chemical, a category that may fall outside customary drug approval and quality rules. In sports, the World Anti-Doping Agency lists SR9009 as a prohibited substance. Athletes who use it can face sanctions if it is detected in a sample. Legal status varies by country, and importation may be restricted. Enforcement practices differ across borders.
1st choice: Surgical amputation - break - prosthesis 2nd choice: Surgical amputation - transplantation of other tissue - plastic reconstruction. 3rd choice: Replantation - reconnection - revascularisation of amputated limb, by microscope (after 1969) 4th choice: Transplantation of cadaveric hand (after 2000)
== Intelligent monitoring and communication == Intelligent packaging monitors a product, package atmosphere, or distribution environment. The system may provide information visually, store it electronically, communicate it to another device, or trigger an active response.
==== Collaboration ==== BTS has collaborated with Starbucks to help support the youth in South Korea. Starbucks prepared limited edition merchandise and beverages that have the same shade of purple reminiscent of a starry night, while playing one of BTS songs "Make It Right" in the store. Through this event, Starbucks raised funds to support The Beautiful Foundation.
Sources: en.wikipedia.org
Alcohol (ethanol/ethyl alcohol) – GABAA receptor positive allosteric modulator Alkyl nitrites (poppers) (e.g., amyl nitrite) – nitric oxide donors, vasodilators, muscle relaxants, inhalants Cannabinoids (e.g., THC, cannabis, synthetic cannabinoids) – cannabinoid CB1 receptor agonists Dissociative hallucinogens (e.g., ketamine, methoxetamine, phencyclidine (PCP)) – ionotropic glutamate NMDA receptor antagonists Entactogens (empathogens) (e.g., MDMA (ecstasy), mephedrone, 6-APB, borax combo) – serotonin–norepinephrine–dopamine releasing agents (SNDRAs), other actions γ-Hydroxybutyric acid (GHB; oxybate) and prodrugs (e.g., GBL, 1,4-BD) – GABAB and GHB receptor agonists Phosphodiesterase PDE5 inhibitors (e.g., sildenafil, tadalafil, vardenafil, avanafil) Psychostimulants (stimulants) (e.g., amphetamine, methamphetamine, cocaine, mephedrone (4-MMC), metaphedrone (3-MMC), MDPV) – norepinephrine–dopamine releasing agents (NDRAs) and/or norepinephrine–dopamine reuptake inhibitors (NDRIs) Serotonergic psychedelics (e.g., 2C-B, 5-MeO-DiPT, 5-MeO-MiPT) – serotonin 5-HT2A receptor agonists
S-formylmycothiol + NADH + + The two substrates of this enzyme are S-(hydroxymethyl)mycothiol and oxidised nicotinamide adenine dinucleotide (NAD+). Its products are S-formylmycothiol, reduced NADH, and a proton. The enzyme belongs to the family of oxidoreductases, specifically those acting on the aldehyde or oxo group of donor with NAD+ or NADP+ as acceptor. The systematic name of this enzyme class is formaldehyde:NAD+ oxidoreductase (mycothiol-formylating). This enzyme is also called NAD/factor-dependent formaldehyde dehydrogenase or S-(hydroxymethyl)mycothiol dehydrogenase.
=== Treatment === The US CDC reports no specific antidote for azide poisoning. A 2021 narrative review identifies several cases of survival from ingestion when the patient is treated with antidotes for cyanide poisoning. From a mechanistic standpoint, hydroxocobalamin is more likely to be helpful than other antidotes such as sodium nitrite and sodium thiosulfate. As a result, the recommended treatment is hemodynamic support and hydroxocobalamin. First responders should use personal protection equipment to protect themselves from azide exposure.
===== The labile iron pool ===== In the cytoplasm, ferrous iron is found in a soluble, chelatable state which constitutes the labile iron pool (~0.001 mM). In this pool, iron is thought to be bound to low-mass compounds such as peptides, carboxylates and phosphates, although some might be in a free, hydrated form (aqua ions). Alternatively, iron ions might be bound to specialized proteins known as metallochaperones. Specifically, poly-r(C)-binding proteins PCBP1 and PCBP2 appear to mediate transfer of free iron to ferritin (for storage) and non-heme iron enzymes (for use in catalysis). The labile iron pool is potentially toxic due to iron's ability to generate reactive oxygen species. Iron from this pool can be taken up by mitochondria via mitoferrin to synthesize Fe-S clusters and heme groups.
Sources: en.wikipedia.org
No. It is an investigational compound without approved therapeutic indications. It is sold for research purposes only in many jurisdictions.
Sports authorities prohibit it because it is not approved for human use and has potential performance-enhancing effects. It appears on anti-doping lists under non-approved or metabolic modulator categories.
Detection usually uses liquid chromatography-tandem mass spectrometry. The method targets the parent compound or its metabolites in urine or blood.
Liquid chromatography with mass spectrometry is a common approach. Ultraviolet detection and nuclear magnetic resonance can support identification when suitable standards are available.